Request Information Download PDF Configure Output Connector
GTM96605-GEN2-T2, USB Adaptive Power Source      ITE/Medical Power supply,  60601-1-4th Ed. , Desktop/External, USB Adaptive Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka \ GTM96605-GEN2-T2
Adaptive USB Power Supply/Quick Charger for Medical and ITE applications for USB PD2.0/3.0 Applications
Information
Model NumberGTM96605-GEN2-T2
DescriptionGTM96605-GEN2-T2, USB Adaptive Power Source ITE/Medical Power supply, 60601-1-4th Ed. , Desktop/External, USB Adaptive Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8"), Output Rating: 60 Watts, Power rating with convection cooling (W) , 3.6-20V in 0.1V increments, Approvals: RCM; CE; PSE; WEEE; VCCI; RoHS; China RoHS; Level VI; Double Insulation; EAC; Ukraine; CB 60601-1 2MOPP; CB 60950; CB 62368; CCC; ETL 62368; ETL; cETLus 60601-1 3rd; cETLus 60601; UL 1310; RCM; S-Mark 60950; S-Mark IEC/EN 60601-1;
Agency Documentshttp://www.globtek.info/certs/GTM96605-GEN2/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000PGI8DEAX
CE EC-Declaration for HouseholdContact GlobTek for more information
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O0c00000PGI8DEAX
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / Desktop / ekstern
TechnologyUSB Adaptive Power Supply AC Adaptor / USB tilpasset strømforsyning AC adapter
CategoryUSB Adaptive Power Source ITE/Medical Power supply / USB Adaptive Power Source ITE/Medical Power supply
Input Voltage Range (V)100-240V~, 50-60Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)60
Output Voltage Range (V)3.6-20
EfficiencyVI
Ingress Protection
Size (mm)
EnclosureUser-added image
Rating Table
Model Number (Final ordering #/Part No to be defined) Output Voltage/Current Levels Available RFQ
GTM96605-GEN2-A1-T2*
5V/4.6A, 5.8V/4.6A, 9V/4.4A, 12V/4A, 15V/3.6A and 20V/3A. (high current)
GTM96605-GEN2-A2-T2*
5V/3A, 5.8V/3A, 9V/3A, 12V/3A, 15V/3A and 20V/3A. (limited current)
* (Final ordering #/Part No to be defined)
SpecificationsOUTPUT CAPABILITIES
The following communication formats are supported: USB PD 2.0/3.0, QC 2.0/3.0, QC 4.0/4.0+


Output Parameters (for USB PD 2.0/3.0 applications):
Communications: Using CC1 pin on USB Type-C connector
Initial Output State: 5V/2A
Advertised USB PD Power Data Objects (PDOs):
      A1 Option: 5V/4.6A, 5.8V/4.6A, 9V/4.4A, 12V/4A,15V/3.6A and 20V/3A
      A2 Option: 5V/3A, 5.8V/3A, 9V/3A, 12V/3A,15V/3A and 20V/3A

A1 Option (standard configuration): Permanently attached (captive) output cable: 1.5m Length, 20AWG, shielded, 5A rated Type-C connector
A2 Option (non-standard configuration):  Detachable output cable. Contact GlobTek for availability.



Note 1: Custom PDOs available upon request. PDO1 must be 5V. PDO2 through PDO7 may be set to any custom voltage from 3.6V to 20V, with a step size of 100mV.

Note 2: For medical applications (etc.) requiring power supply authentication, USB PD Vendor Defined Messages (VDMs) may be implemented to prevent system usage with non-certified power sources. Contact GlobTek for details and for notes on system implementation.

Output Parameters (for QC2.0/3.0 applications):
Communications: Using D+ and D- pins on the USB Type-C connector
Initial Output State: 5V/2A
HVDCP Class B Output Voltages/Currents rating:
      D+             D-                          Output
      0.6V         GND                      5V/4.6A
      3.3V         0.6V                      9V/4.4A
      0.6V         0.6V                      12V/4A
      3.3V         3.3V                      20V/3A
      0.6V         3.3V                      Continuous Mode, adjusts from 3.6V to 20V in 200mV steps
Permanently attached (captive) output cable: 1.5m Length, 20 AWG, shielded


A) GENERAL ELECTRICAL SPECIFICATIONS
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
         90-264 Vac range @ 100% of rated load current
         85-264 Vac range @ 85% of rated load current
         110-370 VDC range @ 100% of rated load current
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 4% measured at the output connector
04. Line Voltage Regulation: +/- 0.5% typical measured at full load
05. Green Power On Indicator LED
06. Output Ripple (Vp-p):100 mV, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected at the end of the output connector
07. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 40% to 70% step load
08. Turn-ON Delay: 1 second maximum @ full load, nominal line
09. Hold-Up Time: 8 mS typical @ nominal input voltage and full load
10. Inrush Current: 30A/60A maximum cold start @ 115/230Vac input
11. Efficiency: Compliant with Efficiency Level VI and CoC Tier 2 standards
12. No Load Standby Power: <0.075 W @ 230Vac  

B) PROTECTIONS
01. Input Protection: Input line fusing and 300Vac MOV
02. Short Circuit/ Overload: Electronically Protected unit will auto recover upon removal of fault

      Output Current Limit: 110% to 135% of rated output current
03. Output Over-Voltage: 25Vdc max

C) SAFETY
01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output,
02. Earth Leakage Current: 3 conductor AC input models < 300uA, N/A for 2 conductor input models
03. Touch Current: 3 conductor AC input models < 20uA, 2 conductor input models < 65uA
04.
Output Isolation Options:
      a) C8 Inlet, Class II (Standard)
      b) C6 or C14 Inlet, Class II FE, Output Isolated from Earth contact (Standard)
      c) C6 or C14 Inlet,  Class I, Output directly attached to Earth contact
05. Means of Protection: 2 x MOPP
06. Compliant Standards: See listings at end of this drawing for specifics

D) EMC

EN 60601-1-2, 4th edition

Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4
     Conducted Emissions: Class B, FCC Part 15, Class B
     Radiated Emissions: Class B, FCC Part 15, Class B
Line Frequency Harmonics EN61000-3-2, Class A

Voltage Fluctuations/Flicker EN61000-3-3

Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2
      Static Discharge Immunity EN61000-4-2, 10kV Contact Discharge, 20kV air discharge
      Radiated RF Immunity EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM.
      EFT/Burst Immunity EN61000-4-4, 4kV/100kHz.
      Line Surge Immunity EN61000-4-5, 2kV differential, 4kV common-mode
      Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM
      Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m
      Voltage Dip Immunity EN61000-4-11, Criteria

E) OTHER
01. MTBF: 300,000 Hours @ 25°C ambient temperature
02. Operating Temperature:

      -10°C to 40°C ambient temperature at full load
      -10°C to 50°C ambient temperature with derating to 80% load
03. Operating Humidity: 0% to 95% relative humidity, non-condensing
04. Storage Temperature: -30°C to 80°C
05. Operating Altitude: 5000m
06. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

F) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Markings: Label or Laser Printed
03. AC Input mechanical options:

      Desktop C6, C8, C14 or C18 IEC Inlet.
      Hybrid option (Desktop or Wall Plug-in) Class I or Class II input

G) SPECIAL OPTIONS

Non-standard - Contact GlobTek for details
01. Detachable USB-C output cordset
02. Special fixed output cord length, 1m, 2m or 3m lengths
03. Custom markings, and marking methods
04. Special housing colors and cordset colors
05. USB Micro-B connector at end of cordset for QC2.0/3.0 applications.
06. Tighter output voltage tolerance
07. Custom PD3.0 PDOs: Output voltages selectable between 3.6V and 20V
08. Constant current/ constant voltage (CC/CV) battery charging, with max charge duration timer

09. USB PD Vendor Defined Messages (VDMs) for power source authentication
 
Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)427 x 405 x 158
Gross Weight (kg)15.6
Label Width (mm)
Label Height (mm)
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")
User-added image
Mates with IEC 60320/C7 Plug

Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2084111M8703(R)India (Type M)BS 546IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)N. American (Type A)NEMA 1-15PIEC 320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C720007
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)

Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) USBC Type (USB Type C) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
No Logo ApplicableCB report IEC60601-1 2005 A1+C1+C2 2016-2-4 and or EN 60601-1:2006 3.1rd Edition 2xMOPP
No Logo CB Report IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 (GTM96605-GEN2-XX)

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added image
 
CCC to GB4943.1-2011 GB9254-2008 GB17625.1-2012
User-added image  CE Certification
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2]Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements (UL 60950-1 Issued: 2007/03/27, Ed: 2 Rev: 2014/10/14) Information Technology Equipment Safety Part 1: General Requirements (CSA C22.2 No. 60950-1 Issued: 2007/03/27 Ed: 2 (R2012) Amd.
User-added image
 
AAMI ES60601-1 Issued: 2012/08/20 Medical Electrical Equipment - Part 1: CAN/CSA-C22.2 No.60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1: IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11:
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added imageConforms to AAMI STD. ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 1310
Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223

 
User-added image  Declaration # ЕАЭС N RU Д-US.АД75.В.01052 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313285, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15? 30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
Australian EMC
User-added image
 
Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageS-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added imageSemko S-Mark-Cert-EN60601-1 3.1rd Edition (http://www.intertek.com/marks/s/)
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request Distributor Stock (Click to order)
5558945V, 5.8V, 9V, 12V, 15V, 20V4.6A, 4.6A, 4.4A, 4A, 3.6A, 3AUSB Type-C Connector
TR9KZ3000USBCFG2R6B5V, 5.8V, 9V, 12V, 15V, 20V4.6A, 4.6A, 4.4A, 4A,3.6A,3AUSB Type-C Connector 86

Request Info

Call
Email
💬
Text
💁
Chat
?
be om tilbud
Kan vi hjelpe deg?
Kan vi hjelpe deg?