ICT/ITE Power Supply
GT-83082-3612-W2E Image | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Image | ![]() | ||||||||||||||||||||||
Information | |||||||||||||||||||||||
Model Number | GT-83082-3612-W2E | ||||||||||||||||||||||
Description | GT-83082-3612-W2E, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC; Current Limited Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, European CEE 7/16 configuration:EN 50075 Europlug 2 PIN, Output Rating: 36 Watts, Power rating with convection cooling (W) , 12V in 0.1V increments, Approvals: CB 60950; Double Insulation; CE; RoHS; WEEE; SIQ; Ukraine; Level VI; GT-83082-3612-W2E, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC; Current Limited Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, European CEE 7/16 configuration:EN 50075 Europlug 2 PIN, Output Rating: 36 Watts, Power rating with convection cooling (W) , 12V in 0.1V increments, Approvals: CB 60950; Double Insulation; CE; RoHS; WEEE; SIQ; Ukraine; Level VI; | ||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GT-83082-W2Z/ | ||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MiZX8EAN | ||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MiZX8EAN | ||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||
Morocco SDoC Declaration | https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MiZX8EAN | ||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000MiZX8EAN | ||||||||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||
Type | Wall Plug-in / Strømforsyning plug-in | ||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC; Current Limited Power Supply AC Adaptor / Regulert switchmode AC-DC;strømbegrenset strømforsyning AC adapter | ||||||||||||||||||||||
Category | ICT/ITE Power Supply / ICT/ITE Power Supply | ||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | ||||||||||||||||||||||
Max Input Current (A) | 1.0A | ||||||||||||||||||||||
Max Output Power Rating (W) | 36 | ||||||||||||||||||||||
Output Voltage Range (V) | 12 | ||||||||||||||||||||||
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 | ||||||||||||||||||||||
Ingress Protection | |||||||||||||||||||||||
Size (mm) | 94(L)*34(W)*91.85 (H) mm maximum | ||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||
Specifications | |||||||||||||||||||||||
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 03. The adapter input/output are full range AC input and +12V DC with 36 watts maximum output. 04. NOMINAL AC INPUT VOLTAGE 1 A maximum, No damage shall be occurred and the input fuse shall not be blown up. 05. POWER CONSUMPTION: 115VAC/230VAC INPUT , power consumption less than 0.1W 06.200 mVp-p maximum Ripple and Noise:At 20 MHz, and output parallel with 0.1uF & 47uF capacitors to ground. Temperature at 25℃, and nominal input voltage (Optional 120 mVp-p maximum Ripple) 07. Turn-ON Delay: 3 Seconds maximum at nominal input voltage 08. Inrush Current: at full load, 25°C, cold start 09. RISE TIME: 100mS maximum at nominal input voltage 10.Efficiency: Compliant with Efficiency Level VI and CoC Tier 2 standards 11. No Load Standby Power: <0.075W @ 230Vac 12. Capacitance load ability(CR mode): 12V,Output set CR mode,and 4000uF capacitor @115Vac/60Hz and 230Vac/50Hz;0% and 100% load 13. OUTPUT REGULATION +/-5% B) PROTECTION 01. Over-current protection 02. Over-voltage protection 03. Short-circuit protection:Short circuit protection is to be included in the construction of the adaptor. The adaptor is designed to withstand continuous current of a short circuit on the output. The adaptor will be short circuit tolerant for an indefinite period. C) SAFETY 01. Dielectric Withstand Voltage: Primary To Secondary: 3000VAC 10mA 1minute or 4242VDC 10mA 1minute 02. 0.25mA maximum, at nominal AC input voltage and frequency 03. Touch Current: <0.25mA @ 240Vac input voltage D) EMC 01. Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4 Conducted Emissions: Class B, FCC Part 15, Class B Radiated Emissions: Class B, FCC Part 15, Class B 02. Line Frequency Harmonics EN61000-3-2, Class A 03. Voltage Fluctuations/Flicker EN61000-3-3 04. Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2 Static Discharge Immunity EN61000-4-2, 4kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m 80-1000MHz, 80% 1KHz AM. EFT/Burst Immunity EN61000-4-4, 1kV/100kHz. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM Power Frequency Magnetic Field Immunity EN61000-4-8, 1A/m Voltage Dip Immunity EN61000-4-11, Criteria E) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: -5 °C TO 45 °C 03. Operating Humidity: 20 ~ 85 % RH. non-condensing 05. Storage Temperature: -20 °C TO +80 °C 06. Storage Humidity:5 ~ 95 % RH. non-condensing 07. Cooling: Cooling shall be with natural convection cooling 08. RoHS 2: Complies with EU 2011/65/EU China SJ/T 11364-2014 F) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||
Qty (ea.)/Carton | 60 | ||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 110*53*92 | ||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||
Master Carton Size (mm) | 460 x 285 x 308 | ||||||||||||||||||||||
Gross Weight (kg) | 8.4 | ||||||||||||||||||||||
Label Width (mm) | 35.0 | ||||||||||||||||||||||
Label Height (mm) | 15.0 | ||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||
Description | European CEE 7/16 configuration:EN 50075 Europlug 2 PINThe prongs of the Europlug are 19 mm long. They consist of a 9 mm long conductive tip of 4 mm diameter with a rounded ending, followed by a 10 mm long flexible insulated shaft of not more than 3.8 mm diameter. The two prongs are not exactly parallel and converge slightly; their centres are 19 mm apart at the tip and 18.6 mm apart at the base. The elasticity of the converging prongs provides sufficient contact force for the Europlug's current rating with a variety of socket-hole arrangements. The entire plug is 35.3 mm wide and 13.7 mm high, and must not exceed these dimensions within 18 mm behind its front plane (this allows for the recesses on many European socket types). The left and right side of the plug are formed by surfaces that are at 45° relative to the horizontal plan. | ||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||
Common output connector options: Click to add to your request.
For a comprehensive list of options, click here Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||
Approvals | |||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||
| |||||||||||||||||||||||
Popular Products (Stock items) | |||||||||||||||||||||||
|
Hva er Level VI effektivitet ?
Nummerene I til VI er en internasjonal effektmerkeprotokoll
som tillater produsenter å designe effektivitetsnivået av et
produkt . Dette er basert på målinger av energieffektiviteten
og forbruk ved no load av eksterne AC/DC adaptere eller
power supply som testes ved ulike lastnivå. No load
forbruket refererer til forbruk som et eksternt power supply
trekker selv om produktet som skal strømforsynes er slått av
eller koplet ut.
Er Level VI et krav ?
Level VI effektivitet er obligatorisk i mange land og regioner
for spesielle produkter eller applikasjoner.
Hva er ECO Design Directive 2009/125/EC ?
ECO-Design Direktivet er lovbelagt i Europa i de siste
energikrav for bevaring av AC/DC adaptere og eksterne
power. Hva er en plug-in AC/DC adapter ?
Plug-in AC/DC adaptere er også kjent som AC adaptere eller
AC/DC convertere og er en type eksternt power supply.
Noen elektriske enheter krever strøm , men har mangel på
interne komponenter for å utlede ønsket spenning og strøm.
Det er her AC adaptere blir benyttet for å konvertere
AC strøm til DC spenning.