ICT / ITE / Medical Power Supply

GTM962254PWWWVVX-XF Image
Model ImageGTM962254PWWWVVX-XF, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/ L Frame/Cage/ Potted Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140W, 12-54V in 0.1V increments, Approvals: CB 60601-1 (pending); CE; China RoHS; UKCA; Morocco; EAC; WEEE; VCCI; Ukraine; Level VI; RoHS; cRUus pending;
Information
Model NumberGTM962254PWWWVVX-XF
DescriptionGTM962254PWWWVVX-XF, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/ L Frame/Cage/ Potted Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140W, 12-54V in 0.1V increments, Approvals: CB 60601-1 (pending); CE; China RoHS; UKCA; Morocco; EAC; WEEE; VCCI; Ukraine; Level VI; RoHS; cRUus pending;
Agency Documentshttp://www.globtek.info/certs/GTM96225xP%20/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000MljATEAZ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000MljATEAZ
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000MljATEAZ
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000MljATEAZ
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O3a00000MljATEAZ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O3a00000MljATEAZ
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/ L Frame/Cage/ Potted Internal / Open Frame/ L Frame/Cage/ Potted Internal
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / Regulert switchmode AC-DC strømforsyning AC adapter
CategoryICT / ITE / Medical Power Supply / ICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)3A
Max Output Power Rating (W)225
Output Voltage Range (V)12-54
Auxiliary/Fan Output Voltage (V)12
Auxiliary/Fan Output Power (W)15W Forced Air, 10W Convection
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionN/A
Size (mm)101.6 (L) x 50.8 (W) x 31.0 (H)
EnclosureUser-added image


 
3D File Downloadhttps://www.globtek.com/dl/GTM962250PWWWVVX-XF.igs
Rating Table
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM962254P13024B-EF*245120
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 85-264VAC, Nameplate: 100-240VAC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Input Current:2.75A typ. @ 85VAC, 1.0A typ. @ 230VAC (full load)
No Load Input Power:< 500mW
Inrush Current:< 75A @ 230VAC (cold start @ 25°C)
Efficiency:90 - 95% typ. (full load)
Power Factor:>0.90 @ 115VAC, >0.85 @ 230VAC, full load

General Output

Turn-on Delay:< 1 second @ 85VAC
Line Regulation:± 0.5% (measured at connector)
Startup Overshoot:< 5% (full load)
Transient Response:< 5% deviation (with 25% load step), recovery to within 1% in 1ms
Hold-Up Time:10ms min. (full load)
Output Indicator:Green LED

Main Output

Output Power:120W/24V
Load Regulation:± 1.0% (measured at connector)
Ripple:< 1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)

Auxiliary Output

Output Power:10W/5V
Load Regulation:± 5.0% (measured at connector)
Ripple:< 100mVpk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)

Protections

Input Protection:MOV transient suppressor, dual fuses (line + neutral)
Over-Voltage Protection:110-130% of main output. Latched-off, cycle AC to reset
Over-Current Protection:Main output: 140% typical, auto-recovery
Auxiliary output: 200% typical, auto-recovery
Short Circuit Protection:Non-latched with auto-recovery
Over-Temperature Protection:NTC temperature sensor embedded in transformer, trip between 115 - 120°, latched-off, cycle AC to reset (auto-recovery available as special option)

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 50°C (full output power), -25°C to 80°C (derated)
Storage Temperature:-30°C to 85°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m max.
Vibration:Conforms to EN60068-2-6, ISO80601-2, EN1789

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth
Intended Medical Application:Type-B or Type-BF
Touch Current:3-conductor input - NC: <25µA, SFC: <200µA
2-conductor input - NC: <65µA, SFC: <140µA
Earth Leakage Current3-conductor input: <200µA
2-conductor input: N/A
Means of Protection:2 x MOPP
Primary-Secondary Bridging Capacitance:Two IEC60384-14 certified Y1 capacitors in series

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN 55011, EN61000-6-3, EN61000-6-4, CISPR11/CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 20KV air discharge (applied to input or output terminals)
Radiated RF Immunity:EN61000-4-3, 20V/m 80-2700MHz, 80% 1KHz AM, 80% 5Hz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, (6VRMS in ISM/amateur bands), 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 30A/m
Voltage Dip Immunity:EN61000-4-11
 

Special Options

  • Custom labels/markings
  • Short term output surge capability
  • Reduced touch current
  • Reduced output ripple
  • Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  • IEC61000-3-2 Class-C line harmonics for LED lighting applications
  • Non-latching (auto-recover) over-temperature protection
  • Potentiometer to adjust/trim output voltage
Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Cellular Packag
Individual Box/Gift Box Color
Master Carton Size (mm)450 x 461 x 182
Gross Weight (kg)8.68
Label Width (mm)TBD
Label Height (mm)TBD
Input Configuration
DescriptionUser-added image
Optional Input Wiring Kits are available:
PN/Ordering NoLengthEnd AEnd B
C810070M6VAR2(R)60IEC 60320 C8JST VAR-2
C1410070M6VAR2(R)60IEC 60320 C13JST VAR-2
VAR2210070M7VAR2(R)73JST VAR-2JST VAR-2
Custom lengths, construction, cable types, ferrites, filters, and termination available upon request.
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageAttention Mark / Refer to operating manual for operating and service instructions

No Logo Applicable

CB for IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1) up to 48V only (pending)

User-added image  
CE Certification
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added imagecRUus UL Recognized Component E341350 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1:14 (2008) (pending)
User-added image  Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
UKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
188876724.0; 5.05.00; 2.00
173596824.05.00
Hva er et IEC 62368-1:2018 power supply `?

IEC 62368-1:2018er benyttes til sikkethet for elektriske og elektroniske apparater angående audio, video , informasjon og kommunikasjonsteknologi, business og kontormaskiner med en gradert spenning som ikke overtiger 600V. Dette er en produktsikkerhet standard som klassifiserer energi kilder, foreskrevne beskyttelser mot disse energi- kilder og gir veiledning ved bruk av - og krav til disse beskyttelser. De foreskrevne beskyttelseskrav er ment å redusere sannsynlighet for smerte, injurier og i tilfelle brann - eiendomsskader. Et IEC 62368 godkjent AC/DC power supply , er et adapter som er testet og sertifisert i henhold til gitte standard.

Erstatter et IEC 62368-1 godkjent power supply et IEC 60950-1 godkjent power supply ? 20 desember 2020 er sikkerhets- standardene IEC 60950-1 og IEC 60065 historie og erstattes av IEC 62368-1 vedrørende tekniske- og audio video produkter. I nord-Amerika vil ETL og UL60950-1 godkjenninger fortsatt gjelde og vil antageligvis bli benyttet inntil videre. Hva er Level VI effektivitet ? Nummerene I til VI er en internasjonal effektmerkeprotokoll som tillater produsenter å designe effektivitetsnivået av et produkt . Dette er basert på målinger av energieffektiviteten og forbruk ved no load av eksterne AC/DC adaptere eller power supply som testes ved ulike lastnivå. No load forbruket refererer til forbruk som et eksternt power supply trekker selv om produktet som skal strømforsynes er slått av eller koplet ut. Er Level VI et krav ? Level VI effektivitet er obligatorisk i mange land og regioner for spesielle produkter eller applikasjoner. Hva er ECO Design Directive 2009/125/EC ? ECO-Design Direktivet er lovbelagt i Europa i de siste energikrav for bevaring av AC/DC adaptere og eksterne power. Hvordan virker et AC/DC adapter ? AC/DC adapteret eller eksternt power supply består av et power supply som er beskyttet i et plasthus tilsvarende en AC plugg, derav navn som plug type, wall plug in,plug in eller plugtop adapter. Adapteret blir montert i vegguttaket og AC spenning blir så omdannet av AC/DC adapteret til DC spenning som er koplet til apparatet via en utgangskabel.
be om informasjon
Call
Email
💬
Text
💁
Chat
?
be om tilbud
Kan vi hjelpe deg?
Kan vi hjelpe deg?