GTM96600-65VV.V-P3, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Potted/Encapsulated in plastic housing, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, See "Blade/Cord Installed" section.
Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths., Output Rating: 65 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: IP68; cETLus 60601-1; CB 62368; RCM; LPS 60950; WEEE; VCCI; Ukraine; Level VI; PSE; PSE; PSE; China RoHS; CE; CB 60950; EAC; UKCA; CB 61158; S-Mark IEC/EN 60601-1; UL 1310; Morocco; GTM96600-65VV.V-P3, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Potted/Encapsulated in plastic housing, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, See "Blade/Cord Installed" section.
Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths., Output Rating: 65 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: IP68; cETLus 60601-1; CB 62368; RCM; LPS 60950; WEEE; VCCI; Ukraine; Level VI; PSE; PSE; PSE; China RoHS; CE; CB 60950; EAC; UKCA; CB 61158; S-Mark IEC/EN 60601-1; UL 1310; Morocco;
Model Number (Final ordering #/Part No to be defined)
Voltage
Amps (A)
Watts (W)
RFQ
GTM96600-2305-P3-IN*
5
4.5
22.5
GTM96600-2305-P3*
5
4.5
22.5
GTM96600-4005-P3*
5
8
40
GTM96600-4006-P3*
6
8
48
GTM96600-4006-P3*
6
6.6
39.6
GTM96600-5409-P3*
9
6
54
GTM96600-4812-P3*
12
4
48
GTM96600-6512-P3*
12
5.41
64.92
GTM96600-6513.2-P3*
13.2
4.92
64.94
GTM96600-2315-P3*
15
1.5
22.5
GTM96600-6515-P3*
15
4.33
64.95
GTM96600-6520-P3*
20
3.25
65
GTM96600-6524-P3*
24
2.7
64.8
GTM96600-6530-P3*
30
2.16
64.8
GTM96600-6536-P3*
36
1.8
64.8
GTM96600-6542-P3*
42
1.54
64.68
GTM96600-6548-P3*
48
1.35
64.8
GTM96600-6554-P3*
54
1.2
64.8
* (Final ordering #/Part No to be defined)
Specifications
Input
Input Voltage:
Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 85% rated load current for 85-264VAC 100% rated load current for 110-370VDC
Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:
Regarding operating temperature a. See below de-rating table for output power capability at alternate temperature b. Extended low-end temperature range available as a custom option
Safety
Dielectric Withstand Voltage:
4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:
Class I: 20µA max. Class II: 85µA max. Class II F2: 20µA max.
Earth Leakage Current
Class I: 300µA max. Class II: N/A
Means of Protection:
2 x MOPP
Output Isolation Options:
Class I: C6 or C14 inlet (output negative tied to Earth contact) Class II: C8 or C18 inlet Class II FE: C6 or C14 inlet (output isolated from Earth contact) Review isolation options by reading our white paper PSU Isolation and Identity.
Earth Continuity Test:
< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:
See listing at end of this datasheet for specific standards
Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:
Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:
EN61000-3-2, Class A
Voltage Fluctuations/Flicker:
EN61000-3-3
Electrostatic Discharge (ESD) Immunity:
EN61000-4-2, 10KV contact discharge, 20KV air discharge
Radiated RF Immunity:
EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:
EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:
EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:
EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:
EN61000-4-8, 3A/m
Voltage Dip Immunity:
EN61000-4-11
Enclosure
Housing:
High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:
Desktop: C6, C7, C14, or C18 inlet Hybrid: Desktop inlet or changeable blades for wall-plug-in style, Class I or Class II input
Markings:
Label and/or pad printed and/or laser-etched into case
Special Options
Removal of LED (cost reduction or aesthetic purpose)
Custom cordsets, various cordage types, and connector types
Custom markings
Short term output surge capability for motors or other high peak current loads. (Available up to 120W for 1 second at nameplate voltage range. Higher levels possible for limited input voltage range, or larger allowed voltage dip.)
Reduced leakage current
Tightened output voltage tolerance
Reduced output ripple level
Reduced output power rating
High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
Low temperature option, down to -40°C
Special housing and cordset colors
"Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
Improved ingress protection (IP) rating
Output Connectors
Several output connector options are available with various output current ratings. GlobTek can supply 10A rated 2.1mm and 2.5mm style DC Power Jacks, to complement our 10A output rated 2.1mm and 2.5mm DC power plugs used on our output cordsets.
See "Blade/Cord Installed" section.
Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths.
Output Configuration
Common output connector options: Click to add to your request.
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
Medical 4th Ed.
EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo Applicable
CB for IEC 60950-1:2005+A1+A2
No Logo Applicable
IEC 61558-1:2005+A1, IEC 61558-2-16:2009+A1
No Logo Applicable
CB for IEC 62368-1:2014 (Second Edition)
Test standard:
EN 55032:2012+AC:2013
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55024:2010
EN 60601-1-2:2015
CHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential
Performance [AAMI ES60601-1:2005 +A1]
IP68
Ingress Protection: ?IP68 to IEC60529:2001 Totally dust tight and Protected against long periods of immersion under pressure
JAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
JAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
Japan: Voluntary Control Council for Interference (VCCI)
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm)
Mark is on the label or Molded in the case
Popular Products (Stock items)
SKU
Volts Out
Current Out (Amps)
Connector
RFQ
Sample Request
1378811
12.0
5.4
1398836
5.0
8.0
1876033
0.0
0.0
1354563
1103831
Hva er Level VI effektivitet ?
Nummerene I til VI er en internasjonal effektmerkeprotokoll
som tillater produsenter å designe effektivitetsnivået av et
produkt . Dette er basert på målinger av energieffektiviteten
og forbruk ved no load av eksterne AC/DC adaptere eller
power supply som testes ved ulike lastnivå. No load
forbruket refererer til forbruk som et eksternt power supply
trekker selv om produktet som skal strømforsynes er slått av
eller koplet ut.
Er Level VI et krav ?
Level VI effektivitet er obligatorisk i mange land og regioner
for spesielle produkter eller applikasjoner.
Hva er ECO Design Directive 2009/125/EC ?
ECO-Design Direktivet er lovbelagt i Europa i de siste
energikrav for bevaring av AC/DC adaptere og eksterne
power. Hvordan virker et AC/DC adapter ?
AC/DC adapteret eller eksternt power supply består av et
power supply som er beskyttet i et plasthus tilsvarende en
AC plugg, derav navn som plug type, wall plug in,plug in eller
plugtop adapter.
Adapteret blir montert i vegguttaket og AC spenning blir så
omdannet av AC/DC adapteret til DC spenning som er
koplet til apparatet via en utgangskabel.