Model Number (Final ordering #/Part No to be defined)
Voltage
Amps (A)
Watts (W)
RFQ
GTM96600-4005-T2*
5
8
40
GTM96600-4005.95-T2*
5.95
6.72
39.98
GTM96600-4808-T2*
8
6
48
GTM96600-5409-T2*
9
6
54
GTM96600-6010-T2*
10
6
60
GTM96600-6011-T2*
11
5.45
59.95
GTM96600-6512-T2*
12
5.41
64.92
GTM96600-6513-T2*
13
5
65
GTM96600-6514-T2*
14
4.642
64.99
GTM96600-6515-T2*
15
4.33
64.95
GTM96600-6516-T2*
16
4.062
64.99
GTM96600-6517-T2*
17
3.823
64.99
GTM96600-6518-T2*
18
3.61
64.98
GTM96600-6519-T2*
19
3.421
65
GTM96600-6520-T2*
20
3.25
65
GTM96600-6524-T2*
24
2.7
64.8
GTM96600-6527-T2*
27
2.407
64.99
GTM96600-6530-T2*
30
2.166
64.98
GTM96600-6535-T2*
35
1.857
65
GTM96600-6548-T2*
48
1.35
64.8
* (Final ordering #/Part No to be defined)
Specifications
Input
Input Voltage:
Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 85% rated load current for 85-264VAC 100% rated load current for 110-370VDC
Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:
Regarding operating temperature a. See below de-rating table for output power capability at alternate temperature b. Extended low-end temperature range available as a custom option
Safety
Dielectric Withstand Voltage:
4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:
Class I: 20µA max. Class II: 85µA max. Class II F2: 20µA max.
Earth Leakage Current
Class I: 300µA max. Class II: N/A
Means of Protection:
2 x MOPP
Output Isolation Options:
Class I: C6 or C14 inlet (output negative tied to Earth contact) Class II: C8 or C18 inlet Class II FE: C6 or C14 inlet (output isolated from Earth contact) Review isolation options by reading our white paper PSU Isolation and Identity.
Earth Continuity Test:
< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:
See listing at end of this datasheet for specific standards
Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:
Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:
EN61000-3-2, Class A
Voltage Fluctuations/Flicker:
EN61000-3-3
Electrostatic Discharge (ESD) Immunity:
EN61000-4-2, 10KV contact discharge, 20KV air discharge
Radiated RF Immunity:
EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:
EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:
EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:
EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:
EN61000-4-8, 3A/m
Voltage Dip Immunity:
EN61000-4-11
Enclosure
Housing:
High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:
Desktop: C6, C7, C14, or C18 inlet Hybrid: Desktop inlet or changeable blades for wall-plug-in style, Class I or Class II input
Markings:
Label and/or pad printed and/or laser-etched into case
Special Options
Removal of LED (cost reduction or aesthetic purpose)
Custom cordsets, various cordage types, and connector types
Custom markings
Short term output surge capability for motors or other high peak current loads. (Available up to 120W for 1 second at nameplate voltage range. Higher levels possible for limited input voltage range, or larger allowed voltage dip.)
Reduced leakage current
Tightened output voltage tolerance
Reduced output ripple level
Reduced output power rating
High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
Low temperature option, down to -40°C
Special housing and cordset colors
"Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
Improved ingress protection (IP) rating
Output Connectors
Several output connector options are available with various output current ratings. GlobTek can supply 10A rated 2.1mm and 2.5mm style DC Power Jacks, to complement our 10A output rated 2.1mm and 2.5mm DC power plugs used on our output cordsets.
+74C operation with an output power of 19.2W; and cold start at -40C
Qty (ea.)/Carton
20
Individual Box/Gift Box Size (mm)
Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)
427 x 405 x 158
Gross Weight (kg)
15.6
Label Width (mm)
35.0
Label Height (mm)
70.0
Input Configuration
Description
IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")
Mates with IEC 60320/C7 Plug
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
Medical 4th Ed.
EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
Test standard:
EN 55032:2012+AC:2013
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55024:2010
EN 60601-1-2:2015
Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL
62368-1:2014 Ed.2]
Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA
C22.2#62368-1:2014 Ed.2]
CHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential
Performance [AAMI ES60601-1:2005 +A1]
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014]
Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3] up to 5A
Compliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
Indoor Use Only - Mark is on the label or Molded in the case
IP41
Ingress Protection: ?IP41 to IEC60529:2001 Protection against
granular foreign bodies - Protected against vertically falling drops of water
JAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
JAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
Korea HU10499-19039A (for GTM96600-6x48-T2,R2(41V-54V)
Korea HU10499-20044A (for GTM96600-6x12-T2(A),R2 9-15V)
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
Japan: Voluntary Control Council for Interference (VCCI)
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm)
Mark is on the label or Molded in the case
Popular Products (Stock items)
SKU
Volts Out
Current Out (Amps)
Connector
RFQ
Sample Request
Hva er et eksternt AC/DC adapter ?
eksterne desktop AC/DC adaptere er også kjent som
AC adaptere eller AC/DC convertere og er en type av
eksterne strømforsyninger.
Noen elektriske apparater krever strøm, men mangler
interne komponenter for å få fram ønsket spenning og
strøm.
Det er her et AC adapter blir benyttet for å omdanne
AC strøm til DC spenning. Hva er et IEC 62368-1:2018 power supply `?
IEC 62368-1:2018er benyttes til sikkethet for elektriske og elektroniske apparater angående audio, video , informasjon og kommunikasjonsteknologi, business og kontormaskiner med en gradert spenning som ikke overtiger 600V. Dette er en produktsikkerhet standard som klassifiserer energi kilder, foreskrevne beskyttelser mot disse energi- kilder og gir veiledning ved bruk av - og krav til disse beskyttelser. De foreskrevne beskyttelseskrav er ment å redusere sannsynlighet for smerte, injurier og i tilfelle brann - eiendomsskader. Et IEC 62368 godkjent AC/DC power supply , er et adapter som er testet og sertifisert i henhold til gitte standard.
Erstatter et IEC 62368-1 godkjent power supply et IEC 60950-1 godkjent power supply ? 20 desember 2020 er sikkerhets- standardene IEC 60950-1 og IEC 60065 historie og erstattes av IEC 62368-1 vedrørende tekniske- og audio video produkter. I nord-Amerika vil ETL og UL60950-1 godkjenninger fortsatt gjelde og vil antageligvis bli benyttet inntil videre. Hva er Level VI effektivitet ?
Nummerene I til VI er en internasjonal effektmerkeprotokoll
som tillater produsenter å designe effektivitetsnivået av et
produkt . Dette er basert på målinger av energieffektiviteten
og forbruk ved no load av eksterne AC/DC adaptere eller
power supply som testes ved ulike lastnivå. No load
forbruket refererer til forbruk som et eksternt power supply
trekker selv om produktet som skal strømforsynes er slått av
eller koplet ut.
Er Level VI et krav ?
Level VI effektivitet er obligatorisk i mange land og regioner
for spesielle produkter eller applikasjoner.
Hva er ECO Design Directive 2009/125/EC ?
ECO-Design Direktivet er lovbelagt i Europa i de siste
energikrav for bevaring av AC/DC adaptere og eksterne
power. Hvordan virker et AC/DC adapter ?
AC/DC adapteret eller eksternt power supply består av et
power supply som er beskyttet i et plasthus tilsvarende en
AC plugg, derav navn som plug type, wall plug in,plug in eller
plugtop adapter.
Adapteret blir montert i vegguttaket og AC spenning blir så
omdannet av AC/DC adapteret til DC spenning som er
koplet til apparatet via en utgangskabel.