Preferred ratings shown below. Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)
Voltage
Amps (A)
Watts (W)
RFQ
GTM96600-4005-T3A*
5
8
40
GTM96600-3005-T3A*
5
6
30
GTM96600-6012-T3A*
12
5
60
GTM96600-6015-T3A*
15
4
60
GTM96600-6018-T3A*
18
3.333
59.99
GTM96600-6024-T3A*
24
2.5
60
GTM96600-6048-T3A*
48
1.25
60
GTM96600-6054-T3A*
54
1.11
59.94
GTM96600-60VV.V-T3A-XXXX
CUSTOM
CUSTOM
CUSTOM
* (Final ordering #/Part No to be defined)
Specifications
Input
Input Voltage:
Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 85% rated load current for 85-264VAC 100% rated load current for 110-370VDC
Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:
Regarding operating temperature a. See below de-rating table for output power capability at alternate temperature b. Extended low-end temperature range available as a custom option
Safety
Dielectric Withstand Voltage:
4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:
Class I: 20µA max. Class II: 85µA max. Class II F2: 20µA max.
Earth Leakage Current
Class I: 300µA max. Class II: N/A
Means of Protection:
2 x MOPP
Output Isolation Options:
Class I: C6 or C14 inlet (output negative tied to Earth contact) Class II: C8 or C18 inlet Class II FE: C6 or C14 inlet (output isolated from Earth contact) Review isolation options by reading our white paper PSU Isolation and Identity.
Earth Continuity Test:
< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:
See listing at end of this datasheet for specific standards
Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:
Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:
EN61000-3-2, Class A
Voltage Fluctuations/Flicker:
EN61000-3-3
Electrostatic Discharge (ESD) Immunity:
EN61000-4-2, 10KV contact discharge, 20KV air discharge
Radiated RF Immunity:
EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:
EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:
EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:
EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:
EN61000-4-8, 3A/m
Voltage Dip Immunity:
EN61000-4-11
Enclosure
Housing:
High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:
Desktop: C6, C7, C14, or C18 inlet Hybrid: Desktop inlet or changeable blades for wall-plug-in style, Class I or Class II input
Markings:
Label and/or pad printed and/or laser-etched into case
Special Options
Removal of LED (cost reduction or aesthetic purpose)
Custom cordsets, various cordage types, and connector types
Custom markings
Short term output surge capability for motors or other high peak current loads. (Available up to 120W for 1 second at nameplate voltage range. Higher levels possible for limited input voltage range, or larger allowed voltage dip.)
Reduced leakage current
Tightened output voltage tolerance
Reduced output ripple level
Reduced output power rating
High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
Low temperature option, down to -40°C
Special housing and cordset colors
"Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
Improved ingress protection (IP) rating
Output Connectors
Several output connector options are available with various output current ratings. GlobTek can supply 10A rated 2.1mm and 2.5mm style DC Power Jacks, to complement our 10A output rated 2.1mm and 2.5mm DC power plugs used on our output cordsets.
Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or package with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
Medical 4th Ed.
EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo Applicable
EU 230V CoC Tier 2, 278/2009, Mar 2014
Book 60335 up to 36 Volts
No Logo Applicable
CB for IEC 60601-1:2005+A1
No Logo Applicable
CB for IEC 60335-1:2010+A1
No Logo Applicable
CB for IEC 60950-1:2005+A1+A2
No Logo Applicable
CB for IEC 62368-1:2014 (Second Edition)
仅适用于海拔5000米以下地区使用
CCC Altitude up to 5000 m
GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
Test standard:
EN 55032:2012+AC:2013
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55024:2010
EN 60601-1-2:2015
Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL
62368-1:2014 Ed.2]
Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA
C22.2#62368-1:2014 Ed.2]
CHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: eneral Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) ( for 5V only)
Certification # TC RU C-US.AR46.B.79113 Custom Union of Russia, Belarus and Kazakhstan
Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential
Performance [AAMI ES60601-1:2005 +A1]
Information Technology Equipment Safety Part 1: General Requirements >Valid without technical revision:01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014]
Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014]
Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3] up to 5A
Compliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
Indoor Use Only - Mark is on the label or Molded in the case
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
IRAM certificate DC-E-G71-002.9 to IEC 60950-1:2005 + A1:2009 +A2:2013
JAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
JAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
Korea HU10499-20041A for GTM96600-6X24-T3, T3A, R3A (21.0V-28.0V)
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
Hva er et eksternt AC/DC adapter ?
eksterne desktop AC/DC adaptere er også kjent som
AC adaptere eller AC/DC convertere og er en type av
eksterne strømforsyninger.
Noen elektriske apparater krever strøm, men mangler
interne komponenter for å få fram ønsket spenning og
strøm.
Det er her et AC adapter blir benyttet for å omdanne
AC strøm til DC spenning. Hva er Level VI effektivitet ?
Nummerene I til VI er en internasjonal effektmerkeprotokoll
som tillater produsenter å designe effektivitetsnivået av et
produkt . Dette er basert på målinger av energieffektiviteten
og forbruk ved no load av eksterne AC/DC adaptere eller
power supply som testes ved ulike lastnivå. No load
forbruket refererer til forbruk som et eksternt power supply
trekker selv om produktet som skal strømforsynes er slått av
eller koplet ut.
Er Level VI et krav ?
Level VI effektivitet er obligatorisk i mange land og regioner
for spesielle produkter eller applikasjoner.
Hva er ECO Design Directive 2009/125/EC ?
ECO-Design Direktivet er lovbelagt i Europa i de siste
energikrav for bevaring av AC/DC adaptere og eksterne
power. Hva er CoCTier 2 for Europa ?
Europeiske CoCTier2 regulering viser krav til effektmål for
eksterne power supply og AC adaptere publisert av
European Commission JRC ( Joint Research Center)
for fornybare energienheter.
Disse mål er frivillige og er ikke bestemt av lover. Hvordan virker et AC/DC adapter ?
AC/DC adapteret eller eksternt power supply består av et
power supply som er beskyttet i et plasthus tilsvarende en
AC plugg, derav navn som plug type, wall plug in,plug in eller
plugtop adapter.
Adapteret blir montert i vegguttaket og AC spenning blir så
omdannet av AC/DC adapteret til DC spenning som er
koplet til apparatet via en utgangskabel.